PAT is a term used for describing a broader change in pharmaceutical manufacturing from static batch manufacturing to a more dynamic approach. It involves defining the Critical Process Parameters (CPPs) of the equipment used to make the product, which affect the Critical Quality Attributes (CQAs) of the product and then controlling these CPPs within defined limits. This allows manufacturers to produce products with consistent quality and also helps to reduce waste & overall costs.
This mechanism for producing consistent product quality & reducing waste presents a good case for utilising continuous manufacturing technologies. The control of a steady state process when you understand the upstream & downstream effects is an easier task as common cause variability is easier to define and monitor.
It would be acceptable to consider that raw materials used to manufacture pharmaceutical products can vary in their attributes e.g. moisture content, crystal structure etc. It would also be acceptable to consider that manufacturing equipment does not always operate in exactly the same fashion due to the inherent tolerance of the equipment and its components. It is therefore logical to say that variability in raw materials married with a static batch process with inherent variability in process equipment produces variable product. This is on the basis that a static batch process produces product by following a fixed recipe with fixed set-points.
With this in mind the PAT drive is to have a dynamic manufacturing process that compensates for variability both in raw materials & equipment to produce a consistent product.
The challenge to date with PAT for pharmaceutical manufacturers is knowing how to start. A common problem is picking a complex process and getting mired in the challenge of collecting and analyzing the data.
The following criteria serve as a basic framework for successful PAT roll-outs: (From A PAT Primer)
In order to implement a successful PAT project, a combination of three main PAT tools is essential:
The long-term goals of PAT are to:
Currently NIR spectroscopy applications dominate the PAT projects. A possible next-generation solution is Energy Dispersive X-Ray Diffraction (EDXRD).4 For a detailed review of PAT tools see Scott,5 or Roggo.6 For an example of application see Gendre.7
Although the FDA's PAT initiative encourages process control based on the real-time acquired data, a small part of PAT applications goes beyond monitoring the processes and follows the PACT (‘Process Analytically Controlled Technology’) approach.8
Fundamental to process analytical technology (PAT) initiatives are the basics of multivariate analysis (MVDA) and design of experiments (DoE). This is because analysis of the process data is a key to understand the process and keep it under multivariate statistical control.
FDA, Guidance for industry: PAT – A framework for innovative pharmaceutical development, manufacturing and quality assurance; September 2004 ↩
Hinz, Process analytical technologies in the pharmaceutical industry: the FDA's PAT initiative; Anal Bioanal Chem, Vol 384, p1036-1042, 2006 ↩
FDA, Pharmaceutical cGMPs for the 21st century – A risk based approach; Final Report, September 2004 ↩
Williams, J: Healthcare Distributor, December 2006/January 2007, page 81. Colorado, United States: E.L.F. Publications, Inc. OCLC 833048096 /wiki/OCLC_(identifier) ↩
Scott, B.; Wilcock, A. (2006). "Process analytical technology in the pharmaceutical industry: A toolkit for continuous improvement". PDA Journal of Pharmaceutical Science and Technology / PDA. 60 (1): 17–53. PMID 17089677. /wiki/PMID_(identifier) ↩
Roggo, Y.; Chalus, P.; Maurer, L.; Lemamartinez, C.; Edmond, A.; Jent, N. (2007). "A review of near infrared spectroscopy and chemometrics in pharmaceutical technologies". Journal of Pharmaceutical and Biomedical Analysis. 44 (3): 683–700. doi:10.1016/j.jpba.2007.03.023. PMID 17482417. /wiki/Doi_(identifier) ↩
Gendre, C.; Genty, M.; Boiret, M.; Julien, M.; Meunier, L. C.; Lecoq, O.; Baron, M.; Chaminade, P.; Péan, J. M. (2011). "Development of a Process Analytical Technology (PAT) for in-line monitoring of film thickness and mass of coating materials during a pan coating operation" (PDF). European Journal of Pharmaceutical Sciences. 43 (4): 244–250. doi:10.1016/j.ejps.2011.04.017. PMID 21569842. https://hal.archives-ouvertes.fr/hal-01631589/file/Development_of_a_process_analytical_technology.pdf ↩
Nagy, B; et al. (2017). "In-line Raman spectroscopic monitoring and feedback control of a continuous twin-screw pharmaceutical powder blending and tableting process". International Journal of Pharmaceutics. 530 (1–2): 21–29. doi:10.1016/j.ijpharm.2017.07.041. PMID 28723408. /wiki/Doi_(identifier) ↩