Menu
Home Explore People Places Arts History Plants & Animals Science Life & Culture Technology
On this page
Differential nonlinearity

Differential nonlinearity (acronym DNL) is a commonly used measure of performance in digital-to-analog (DAC) and analog-to-digital (ADC) converters. It is a term describing the deviation between two analog values corresponding to adjacent input digital values. It is an important specification for measuring error in a digital-to-analog converter (DAC); the accuracy of a DAC is mainly determined by this specification. Ideally, any two adjacent digital codes correspond to output analog voltages that are exactly one Least Significant Bit (LSB) apart. Differential non-linearity is a measure of the worst-case deviation from the ideal 1 LSB step. For example, a DAC with a 1.5 LSB output change for a 1 LSB digital code change exhibits 1⁄2 LSB differential non-linearity. Differential non-linearity may be expressed in fractional bits or as a percentage of full scale. A differential non-linearity greater than 1 LSB may lead to a non-monotonic transfer function in a DAC. It is also known as a missing code.

Differential linearity refers to a constant relation between the change in the output and input. For transducers if a change in the input produces a uniform step change in the output the transducer possess differential linearity. Differential linearity is desirable and is inherent to a system such as a single-slope analog-to-digital converter used in nuclear instrumentation.

Related Image Collections Add Image
We don't have any YouTube videos related to Differential nonlinearity yet.
We don't have any PDF documents related to Differential nonlinearity yet.
We don't have any Books related to Differential nonlinearity yet.
We don't have any archived web articles related to Differential nonlinearity yet.

Formula

DNL(i) = V out ( i + 1 ) − V out ( i ) ideal LSB step width − 1 {\displaystyle {\text{DNL(i)}}={{V_{\text{out}}(i+1)-V_{\text{out}}(i)} \over {\text{ideal LSB step width}}}-1}

Effects of DNL

  • If the DNL of an ADC is smaller than -1, missing codes appear in the transfer function, i.e. there are codes for which there is no input voltage to get the code at the ADC output.
  • If the DNL of a DAC is bigger than 1, the transfer function of the DAC becomes non-monotonic. A non-monotonic DAC is especially not desired in closed-loop control application as it may cause stability problems, i.e. it may cause oscillations.

See also

References

  1. INL and DNL definitions "A DNL error specification of less than or equal to 1LSB guarantees a monotonic transfer function with no missing codes. " https://www.analog.com/en/technical-articles/inldnl-measurements-for-types-of-highspeed-adcs.html https://www.analog.com/en/technical-articles/inldnl-measurements-for-types-of-highspeed-adcs.html